Phoenix-E - Exterior Acoustical Panel Systems
Phoenix-E - Creating Better Workplaces Worldwide
Home | Online Catalog | About Us | Literature | RFQ | Contact Us
Call Us Today: 800.241.4207, E-mail: info@phoenix-e.com
  Noise Control
Solutions
Controlled and Critical Environments Functional Buildings, Enclosures, Mezzanines and Vertical Conveyors H-Occupancies / Hazardous EnvironmentsAcoustical Test FacilitiesLiterature

All Categories > Noise Control Solutions > SonoCon Exterior Acoustical Panel Systems > Exterior Acoustical Panel Systems  
    Print Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Exterior Acoustical Panel Systems



    Email Email This Page  
    Save To Favorites Save To Favorites
  


    Noise Control Enclosures - Soundwalls - Absorptive Panels
  • Acoustical Performance Independently Tested & Rated.
  • Rugged Construction For Outdoor Environments.
  • Non-combustible Construction.
  • Engineered & Factory Fabricated.



Details · Materials & Construction · Acoustical Performance

Details
    SonoCon Class One, Type E exterior noise control systems are fabricated of acoustical panels which provide substantial sound absorption and transmission loss performance.

    Acoustical Performance
    With high transmission loss and sound absorption properties, the SonoCon sound barriers acoustically isolate equipment and processes from the community and in-plant personnel. Energy within the enclosure is absorbed preventing both reverberant buildup and unwanted reflections which might direct or broadcast the high noise levels into nearby areas.

    Construction
    Constructed of galvanized steel, the acoustical barriers are erected of internally reinforced, tongue and groove panels into a structural framework. SonoCon panels can easily accommodate 15'-0" spans and assemblies can be erected to virtually any height.

    Engineered to withstand typical outdoor environments, SonoCon Soundwall systems can accommodate wind speeds to 95 MPH and seismic zone 4 loads.

    Engineering
    All SonoCon systems are engineered to meet the structural requirements specified by local building codes.

    Installation
    Shipped as prefabricated components, SonoCon sound walls and enclosures are quickly installed integrating the acoustical panels with the structural framing.



Materials & Construction



    The SonoCon acoustical barrier shall be installed on a foundation or other supporting structure adequate to accommodate the structural loads. The acoustical assembly shall be constructed of SonoCon Class 1-E acoustically rated panels. Panels are to be 4-1/4" thick fabricated of G90 galvanized steel.

    Panels used as sound barriers shall be constructed of tongue and groove acoustical panels with the groove facing downwards. The panels shall be fabricated with 18 gage steel exterior face sheets. Panels used for noise absorption only shall be fabricated with 22 gage exterior backing sheets. All panels will be constructed with 20 gage perforated steel sheet feeing the noise source. The perforated sheet shall consist of 3/32" diameter holes on 3/16" staggered centers. The sound absorbing core shall be non-combustible, inorganic, and inert. It shall be vermin proof and mildew resistant.

    The panels shall be internally reinforced with 16 gage member designed to safely withstand the lateral loads imposed on the spans shown on the drawing in accordance with the specified building code. Stiffener spans should not exceed 24". Perimeter and internal reinforcing steel shall be welded to the solid face sheet to form a rugged, unitized acoustic component. Weld centers should not exceed 3". The acoustical fill shall be packed under compression without voids so as to secure the acoustic core even under severe vibration.

    Attachment to the structural framing or existing wall surfaces shall be adequate to support the specified live and dead loads. The acoustical core shall be protected with an acoustically permeable, UV resistant, non-hygroscopic membrane placed between the acoustical fill and perforated sheet. Mylar, Tedlar or similar films are not acceptable due to weather degradation.

Acoustical Performance
Sound Transmission Loss (dB)
Octave Band 2 3 4 5 6 7 -
Center Frequency (Hz) 125 250 500 1000 2000 4000 STC
dB 22 29 40 48 54 60 41
ASTM E90
             
Minimum Absorption Coefficients
Octave Band 2 3 4 5 6 7 -
Center Frequency (Hz) 125 250 500 1000 2000 4000 NRC
dB 0.86 1.09 1.22 1.06 1.05 1.04 1.10
ASTM C-423




 MORE IMAGES 

· Acoustical-enclosure-outdoor-for-mechanical-equipment

· Outdoor-Acoustical-Enclosure-for-cement-batch-plant-

· Large-SonoCon-enclosure


 DOWNLOADS 

 width= SonoCon-Class-1E-Exterior-Panels-Brochure
(PDF, 745KB)

 width= Noise Control Brochure
(PDF, 3746KB)


Request Information
 

 
GO

Applications

• Cogeneration
• Power Plants
• Water Treatment Plants
• Gas Utilities
• Cooling Towers
• Anechoic Rooms
• Control Rooms
• Explosion Proof Facilties

Literature

SONO-CON Literature
• Understanding Noise
   Control
• Noise Control
   Manufacturing - Power    Generation - Processing
• SonoCon HP Sound
   Absorption